Donatoni Macchine
Technical troubleshooting sheet Emergency diagnostic procedure

Before proceeding, carefully read the

SAFETY INSTRUCTIONS

DescriptionA-axis overcurrent alarm

SeverityModerate02 / 05

Authorized personnelMachine operator

Required PPE:

image-20240327-084216.png

Description

During automatic working cycles, the PLC may generate an overcurrent alarm for each individual axis when the maximum load capacity of the relevant motor is exceeded.

Symptoms

…..

Possible causes

  1. Instantaneous excessive load in the A direction

  2. A-axis motor malfunction

Possible solutions

  1. Press the reset button to reset the error, then press the emergency stop button, re-enable the controls and resume normal operation;