Donatoni Macchine
Technical maintenance sheet Controlled procedure

Before proceeding, carefully read the

SAFETY INSTRUCTIONS

Intervalevery 2000 working hours

Operation complexityLow01 / 05

Authorized personnelMachine operator

Required PPE:

image-20240327-084216.png
  1. Shut down the machine correctly and turn the switch to the OFF position

    image-20260626-082036.png
  2. Remove the cover by releasing it from the bottom and moving it upward

    image-20260626-083223.png
    image-20260626-083545.png
  3. Clean the filter using an air gun

    image-20260626-083454.png
  4. Reassemble everything by carrying out the procedure in reverse order

;